AirSim® Difficult Airway

Share this article:

Clinical skills training · DA91100

AirSim® Difficult Airway

TruCorp logo

AirSim Difficult Airway Trainer

Product overview

The AirSim Difficult Airway is an adult intubation head which provides a solution for varying degrees of difficulty when practicing airway management. This versatile model ranges from challenging to very difficult to intubate, facilitating a variety of training scenarios for advanced users . The AirSim Difficult Airway has been designed to improve management of the unanticipated difficult intubation in accordance with the recommended guidelines.

Description

INTERACTIVE DEMO:

Explore the AirSim Difficult Airway

Click the hotspots to explore key features and watch short demo videos, designed to give a quick, clear walkthrough of the AirSim Difficult Airway.

View product video

Versatile | Anatomically Accurate | Guidelines Compliant

AirSim Difficult Airway is an airway management trainer designed to replicate a wide range of challenging airway scenarios from moderate to severe. It enables instructors to rapidly configure airway presentations – including laryngospasm, displaced larynx, and more – so learners can practice structured airway escalation and emergency airway access in a controlled environment.

Anatomically Accurate

AirSim® Airway delivers true-to-life anatomical visualisation of the following landmarks:

Nasopharynx:

  • Nasal Turbinates

Oropharynx:

  • Tongue
  • Uvula
  • Vallecula

Laryngopharynx:

  • Epiglottis
  • Arytenoid cartilage
  • Oesophageal opening

Larynx:

  • Glottis
  • Vocal cords

Lower Airway:

  • Tracheal rings
  • Carina
  • Bronchus
  • Bronchioles
Challenging Airway Scenarios On Demand

Fast configuration of key airway presentations including:

  • Laryngospasm
  • Displaced Larynx
  • Tongue Oedema
  • Trismus
  • Receding/Protruding Mandible
  • Restricted Neck Mobility

Designed for scalable programme delivery, the model uses cost-effective consumables that are quick and easy to interchange.

*Extreme Difficult Airway available upon request, the internal airway has an enlarged tongue, swollen posterior cartilages and an elongated epiglottis to provide a very challenging airway management user experience. Contact our team today for more information.

Instructor-Controlled Variability

All features are quickly adjustable, allowing facilitators to run isolated challenges (e.g., trismus only) or combined complexity (e.g., laryngospasm + limited neck mobility) to align with learning objectives, assessment requirements, and cohort size.

Real-Time Feedback

Integrated visual indicators of stomach inflation and lung expansion provide immediate feedback to reinforce correct ventilation and airway management technique.

Portable & 5-Minute Set-Up

Delivered ready to use in a durable carry case for straightforward transportation and safe storage – supporting consistent deployment across multiple training locations.

Set-up time is under 5 minutes – simply remove the manikin from the carry case, then spray the airway and nasal passage generously with the lubricant provided.

AirSim Difficult Airway Settings

Medical student learning cricothyroidotomy on AirSim Difficult Airway

Difficult Airway Features:

1. Laryngospasm
  • Adjustable from normal to complete airway obstruction.
  • Sudden closure of the vocal cords can be simulated.
  • Upon successful user action, laryngospasm can be mechanically reversed to provide positive feedback.
2. Displaced Larynx
  • Ability to displace the larynx into a more anterior position to make visualisation of the vocal cords more challenging.
  • Adjustable to provide various levels of difficulty.
3. Tongue Edema
  •  The tongue can be swollen to simulate various degrees of tongue angioedema. 
4. Trismus
  • Ability to grossly restrict mouth opening to make insertion of airway devices more challenging.
5. Adjustable Mandible
  • Various degrees of malocclusion, one mandibular variant and two maxillary variants. 
  • Overbite and underbite features simulated.
6. Restricted Neck Mobility
  • Ability to simulate cervical arthropathy through restricting the range of motion of cervical spine.
  • Neck lock / Head rotation restriction.
7. Cric & Tracheostomy
  • Easy identification of sternal notch, tracheal rings & cricoid and laryngeal cartilages.
  • Interchangeable larynx allows quick and easy repeated use.
  • Wraparound replaceable neck skin rotates for 10-15 incisions.

All features can be activated quickly and effortlessly by the instructor to create a more challenging or easier experience. The features can be used in isolation or combined to deliver a scenario with numerous variations of difficulty.

  • Student using the Difficult Airway intubation trainer
  • Medical student learning cricothyroidotomy on AirSim Difficult Airway
  • AirSim Difficult Airway Settings
  • DS2 4265 1 | TruCorp | Medical Training Manikins

Medical Procedure Training In:

  • Needle and surgical cricothyroidotomy
  • Percutaneous tracheostomy
  • Double naso-tracheal intubation
  • Bag-valve mask (BVM) ventilation techniques
  • Full range of supraglottic device insertion
  • Direct and video laryngoscopy including Sellick Maneuver
  • Fibre optic intubation & examination
  • ET intubation
  • Combi tube insertion
  • Nasogastric (NG) tube insertion techniques

Add the TruCorp Bronchial Tree to enable:

  • Diagnostic bronchoscopy
  • Single lung isolation techniques

TRUCORP SIMULATORS:

Compatible Training Solutions

TruMan Trauma Adult – Lifelike training in advanced airway management skills, CPR and emergency surgical procedures for life threatening trauma situations.

The Smart Airway® Adult offers a sensor-driven simulation platform enabling validated assessment and personalized feedback for competency training across fundamental and advanced airway techniques.

Emergency Medicine Practice on Smart Truman Trauma Adult

TruMan trauma adult

Smart Airway Instructor Mode

SMART AIRWAY ADULT

TRUCORP SIMULATORS:

Compatible Training Solutions

TruMan Trauma Adult – Lifelike training in advanced airway management skills, CPR and emergency surgical procedures for life threatening trauma situations.

The Smart Airway® Adult offers a sensor-driven simulation platform enabling validated assessment and personalized feedback for competency training across fundamental and advanced airway techniques.

TruCorp medical training manikins are designed and built for students and healthcare professionals including anaesthetists, emergency medicine doctors, paramedics and more.

TruCorp also has produced a range of simulation solutions to facilitate training in different medical fields:

Compare Adult Airways

AirSim Advance X
AirSim Advance X

AirSim Advance X

AirSim Advance X

View Now

Endo/Nasotracheal intubation

Included

Bag valve mask ventilation

Included

Supraglottic device insertion

Included

Direct/video laryngoscopy

Included

NG tube insertion

Included

3-2-1 Warranty

3-Years

Needle/surgical cricothyroidotomy

—

Percutaneous tracheostomy

—

Bronchoscopy techniques

Optional Add-On

Difficult Features (Laryngospasm etc)

—

Smart Feedback

—

AirSim Combo X
AirSim Combo X - Airway Management

AirSim Combo X – Airway Management

AirSim Combo X

View Now

Endo/Nasotracheal intubation

Included

Bag valve mask ventilation

Included

Supraglottic device insertion

Included

Direct/video laryngoscopy

Included

NG tube insertion

Included

3-2-1 Warranty

3-Years

Needle/surgical cricothyroidotomy

Included

Percutaneous tracheostomy

Included

Bronchoscopy techniques

Optional Add-On

Difficult Features (Laryngospasm etc)

—

Smart Feedback

—

AirSim Difficult Airway
AirSim Difficult Airway - Airway Management

AirSim Difficult Airway – Airway Management

AirSim Difficult Airway

View Now

Endo/Nasotracheal intubation

Included

Bag valve mask ventilation

Included

Supraglottic device insertion

Included

Direct/video laryngoscopy

Included

NG tube insertion

Included

3-2-1 Warranty

1-Year

Needle/surgical cricothyroidotomy

Included

Percutaneous tracheostomy

Included

Bronchoscopy techniques

Optional Add-On

Difficult Features (Laryngospasm etc)

Included

Smart Feedback

—

Smart Airway Adult
Smart Airway Adult - Airway Management

Smart Airway Adult – Airway Management

Smart Airway Adult

View Now

Endo/Nasotracheal intubation

Included

Bag valve mask ventilation

Included

Supraglottic device insertion

Included

Direct/video laryngoscopy

Included

NG tube insertion

Included

3-2-1 Warranty

1-Year

Needle/surgical cricothyroidotomy

Included

Percutaneous tracheostomy

Included

Bronchoscopy techniques

—

Difficult Features (Laryngospasm etc)

—

Smart Feedback

Included

Package Contents

Package Contents

Parts & accessories

Videos

AirSim® Difficult Airway | Advanced Difficult Airway Management Training ManikinDifficult Airway Internal View

FAQs

What skills can I teach using the AirSim Difficult Airway?

Learners will gain proficiency in the below procedures:

1. Laryngospasm
2. Displaced larynx
3. Tongue Edema
4. Receding / protruding Mandible
5. Trismus
6. Neck lock / Head rotation restriction
7. Front of Neck airway management

What package contents will arrive with my order?

• 1 AirSim Difficult Airway ready-to-use (DA91100)
• 1 AirSim Difficult Airway Carrier Case (ABAG01)
• 100ml Bottle Of Lubrication (TL001)
• 5 Larynx Inserts (NLX050 – 1 supplied on the manikin and 4 spare)
• 1 Wraparound Neck Skin (RSN2005 – supplied on manikin)
• 2 sets of adhesive pads (attachable to suction cups for increased stability if required)

Do I need to order replacement consumables?

• TruCorp lubrication 100ml (TL001)
• Larynx inserts (NLX050)
• Wraparound neck skins (RSN2005)
• Super Saver Cric Pack (100 Procedures) (ATP0100)

How many procedures will each consumable facilitate?

• 1 larynx insert (NLX050) facilitates 1 surgical cricothyroidotomy and 2-3 percutaneous tracheostomy procedures
• 1 wraparound neck skin (RSN2005) facilitates approx. 10-15 incisions, the skin is designed to be rotated around the neck to maximize usage
• All consumables are quick and easy to interchange so there is no disruption to teaching time

What type of lubrication can be used during intubation practice?

We recommend TruCorp’s silicone based lubrication for best practice, but alternatives can be used provided they are water or silicone-based lubricants. Avoid using petroleum/oil based lubricants as this will degrade the material over time.

Does the AirSim Difficult Airway require assembly?

No, this training manikin is delivered ready to use so you can begin training straight away! Generously spray the oral/nasal passages and equipment with the lubrication provided.

What equipment sizes are recommended?

• Size 7.0-7.5mm ID for nasal intubation
• Size 8.0-9.0mm ID for oral intubation
• Large / Size 6 for BVM ventilation mask
• Size 3-5 for LMA laryngeal masks
• Similar respective sizes for other supraglottic devices

Does the manikin provide user feedback to indicate successful or failed procedures?

Yes, if successfully intubated the two lung bags will inflate. If the airway device is incorrectly placed in the oesophagus, the stomach bag will inflate.

My AirSim Difficult Airway manikin needs repairing. How can I arrange this?

Please direct all warranty and repair requests/inquiries to:

What warranty comes with the AirSim Difficult Airway?

The AirSim Difficult Airways comes with a 1-year warranty. Warranty begins from the date of delivery.

What can I use to clean the manikin?

Thoroughly wash the airway in warm water. Please use warm soapy water or similar until all visible foreign matter and residue is removed.

Mild detergents or enzymatic cleaning agents may be used on the airway at the proper dilution. The detergent must not contain skin or mucous membrane irritants.

Please do not use any of the following when cleaning the AirSim® product range:
• Germicides, disinfectants or chemical agents such as glutaraldehyde (e.g. Cidex®)
• Ethylene oxide, phenol-based cleaners or iodine-containing cleaners

In response to the recent COVID-19 pandemic, we recommend this additional step to ensure the product is fully sanitized:

Generously spray alcohol spray or gel (minimum 75% alcohol) and wipe off. Repeat 3-4 times to fully disinfect the product. This can be done on the silicone skin and the latex airway.

Options and configurations

Option Supplier SKU
Bronchi: No Bronchi / Skin Tone: Dark AirSim Difficult Airway – Dark Skin
Bronchi: No Bronchi / Skin Tone: Light AirSim Difficult Airway – Light Skin
Bronchi: Add Bronchi / Skin Tone: Dark AirSim Difficult Airway – Dark Skin – Bronchi
Bronchi: Add Bronchi / Skin Tone: Light AirSim Difficult Airway – Light Skin – Bronchi

Product photographs

Medical student learning cricothyroidotomy on AirSim Difficult Airway
Medical student learning cricothyroidotomy on AirSim Difficult Airway
Instructor teaching students how to intubate using AirSim Difficult Airway
Instructor teaching students how to intubate using AirSim Difficult Airway
Cricothyroidotomy on AirSim Difficult Airway
Cricothyroidotomy on AirSim Difficult Airway
Airway Management
Airway Management
Difficult Airway Trainer
Difficult Airway Trainer
Difficult Airway Displaced Larynx
Difficult Airway Displaced Larynx
Tongue Edema training manikin
Tongue Edema training manikin
Difficult Airway Laryngospasm
Difficult Airway Laryngospasm
AirSim Difficult Airway small image
AirSim Difficult Airway small image
Difficult Airway Tongue Edema
Difficult Airway Tongue Edema

Resources and downloads

User Manual- AirSim Difficult Airway 040625

Super Saver Cric Training Pack Product Sheet

AirSim Difficult Airway 2026 Product Information Sheet

View the original product article

Plan your training

Contact Survival Technology to discuss this product and your training requirements.

Contact Survival Technology

Quote Cart
Scroll to Top