Suprapubic Insertion (Ultrasound Guided) Unit (Dark Skin Tone) (60873)

Share this article:

Product overview · 60873

Suprapubic Insertion (Ultrasound Guided) Unit (Dark Skin Tone)

Limbs & Things logo

Suprapubic Insertion (Ultrasound Guided) Unit (Dark Skin Tone) — product photograph

Overview

The Suprapubic Insertion Unit can be used independently or combined with another catheterization trainer for a real to life simulation. This module allows for the practice of the surgical procedure of suprapubic catheterization and is made of echolucent silicone for ultrasound guided procedures.

What are the features of the suprapubic catheterization simulator?

  • Ultrasound bladder scanning – allows for ultrasound identification of urine present in the bladder, reducing risks associated with CaUTI
  • Ultrasound guided Suprapubic Catheterization – allows for advanced procedure training in Urology
  • Allows for the practice of Blind Suprapubic Catheterization

Watch the product video ↗

Watch the product video ↗

Features

Suprapubic Insertion (Ultrasound Guided) Unit (Dark Skin Tone) — additional product view
Suprapubic Insertion (Ultrasound Guided) Unit (Dark Skin Tone) — additional product view
Highlights
  • More robust design means longer lasting models, keeping on-going costs lower
  • Ability to view catheter path when modules are used outside of the Pelvic Shell
  • Improved Water System
  • Softer, more realistic anatomy
  • Improved internal anatomy to allow for smoother insertion of catheter into the bladder
Realism
  • Anatomically accurate bladder
  • New ultrasound bladder scanning aides in identification of urine in the bladder, reducing risks associated with CaUTI
  • Ultrasound guided catheterization allows for more advanced Urology training
Versatility
  • Modules are interchangeable, and fit with the Male and Female Urinary Catheterisation models
  • Ability to view the path of the catheter during procedures
  • Non-drip valve
Anatomy
  • Pubic bone
  • Rectus sheath
  • Anatomically accurate bladder
Simulated Patient
  • Can be used with a standardised patient to help improve communication skills
Cleaning
  • Drain all water from the product
  • Remove all catheters from the trainer
  • Clean product surface with soft, damp cloth and mild detergent
  • Allow trainer to dry completely before storing
Safety
  • Components of the trainer are latex free
  • Always deflate the balloon before removing a catheter
  • To reduce the risk of bacteria and mould, add a sterilisation fluid to the water, such as Milton Antifungal agent

Skills

Skills Gained

  • Suprapubic catheter management on female anatomy
  • Blind and ultrasound guided suprapubic catheter insertion
  • Ultrasound bladder scanning on a full bladder

Contains

This simulation model is supplied with an antifungal agent. (Use as per instructions on the packet.)

Weight & Dimensions

  • Weight: 4 kg
  • Width: 25 cm
  • Height: 27 cm
  • Length: 38 cm

See weight and dimensions

Works with

Curriculum

Curriculum references and learning areas listed for this product. Edition dates are retained from the supplier’s references.

UK General Surgery Specialist Training

Suprapubic catheter insertion. Intercollegiate Surgical Curriculum Programme (ISCP) General Surgery Curriculum, 2021, P69.

UK Medical Undergraduate

Therapeutic Procedures 22. Male and female urinary catheterization. Passing a tube into the urinary bladder to permit drainage of urine, in make and female patients. Outcomes for Graduates (Tomorrow's Doctors), 2016, Appendiz 1 Practical Procedures for Graduates, P14.

UK Physician Associate

2.4.7 Renal and genitourinary system – Undertake male and female urinary catheterization. Competence and Curriculum Framework for the Physician Assistant, 2012, 2.4 Specification of core procedural skills.

UK Postgraduate Medicine FY1 & FY2

Core procedure requirements. 13. Uretheral catheterisation (male) guidance. 14. Urethral catheterisation (female) guidance. Foundation Programme Curriculum, 2012, updated for 2016, Core Procedure Requirements, P9.

UK Postgraduate Nursing

The suggested structure for gaining competence in catheterisation: – Observe model/manikin being catheterised – Practise catheterisation on a model/manikin under supervision until confident – Insert and secure urethral catheters – Manage suprapubic catheters – Enable individuals to carry out intermittent self-catheterisation. Catheter Care Guidance for RCN Nurses, Second Edition, 2012, Pg 3. Pg 12.

UK Pre-Registered Nursing

Annexe B: Nursing Procedures. 6.1 "observe and assess level of urinary and bowel continence to determind the need for support and intervention." 6.2: "select and use appropriate continence products; insert, manage and remove catheters for all genders; and assist with self-catheterisation when required." 6.3: "manage bladder drainage." Future Nurse: Standards of proficiency for registered nurses, 2018, P35.

UK Urology Specialist Training

Technical Skills and Procedures – Competently insert a suprapubic catheter, with ultrasound guidance as appropriate – Complex catheterisation. Intercollegiate Surgical Curriculum Programme (ISCP) Urology Syllabus, August 2021, P58.

Product Downloads

User Guide Suprapubic Insertion Unit V5 PDF | 1.5 MB ↗

Product Brochure Catheterisation Range Brochure V4 PDF | 1.3 MB ↗

Product Brochure 导管训练模型系列 – CN PDF | 2 MB ↗

Product Brochure Producktauswahl Katherisierungstrainer – DE PDF | 1.8 MB ↗

Product Brochure Gama de Simuladores de Sondaje Vesical – ES PDF | 1.8 MB ↗

Product Brochure Gamme de Simulateurs de Sondage Urinair – FR PDF | 1.8 MB ↗

Specifications

Weight & Dimensions
  • Weight: 4 kg
  • Width: 25 cm
  • Height: 27 cm
  • Length: 38 cm

Dimensions and weights are reproduced in the form provided by the supplier. Entries labelled “Box” refer to packaging.

Options

View the available configurations on the original product article ↗

Discuss your training requirements

Contact Survival Technology about this product, its configuration and your teaching requirements.

Contact Survival Technology

Quote Cart
Scroll to Top